Nitrogen
Evaporators Menu: |
|
| Instrument Name | MULTIVAP | MULTIVAP | MULTIVAP | ||
| Number of Sample Positions | 64 | 100 | 30 | 48 | 96 |
| Instrument Catalog Number ( Order Online* ) |
11364 | 11300 | 11830 | 11848 | 11896 |
| Overall
Dimensions w x d x h |
19 x 14 x 34 in 48 x 36 x 86 cm |
14 x 16 x 22 in 36 x 41 x 56 cm |
22 x 16 x 22 in 56 x 41 x 56 cm |
||
| Sample
Holder and Gas Manifold Layout |
Square 8 x 8 Array |
Square 10 x 10 Array |
Rectangular Single 5 x 6 Array |
Rectangular Single 6 x 8 Array |
Rectangular Double 6 x 8 Array |
| Test
Tube Diameter mm |
10-30 mm | 10-22 mm | 20-30 mm | 10-20 mm | 10-20 mm |
| Gas Flow Control | Every Row of 8 |
Every Row of 10 |
Every
Row of 5 |
Every
Row of 6 |
Every Row of 6 |
| Gas
Flow Meter Liters/Minute |
0-30 lpm | 0-15 lpm | 0-20 lpm | Dual 0-15 lpm | |
| Gas
Pressure Regulator Range |
Standard 0-30 psig |
Standard 0-30 psig |
Standard 0-30 psig |
Standard 0-30 psig |
|
| Stainless Steel Needles Length & Gauge |
4in x 19ga 10cm x 19ga |
4in x
14ga 10cm x 14ga |
4in x
19ga 10cm x 19ga |
4in x 19ga 10cm x 19ga |
|
| Hoist Assembly | Dual Band Springs | ||||
* When ordering options listed below, please add the appropriate suffix to the catalog number when ordering.
| Instrument Standard Features | Instrument Options |
| Laboratory grade materials stand up to organic solvents. One piece manifold raises and lowers. Removable rack handles a batch of samples. |
Acid resistant coating (-RT) FEP coated needles (-T) |
| Model
Number ( Order Online* ) |
10115-CE | 5072-CE | 10072-CE |
| Heater Type | Water Bath | Water Bath | Water Bath |
| Inside
Dimensions w x d x h |
11 x 11 5.0 in 28 x 28 x 13 cm |
7 x 8 x
1.8 in 18 x 21 x 5 cm |
7 x 8.4 x 1.8 in 18 x 21 x 5 cm |
| Outside
Dimensions w x d x h |
19 x 14 x 6 in 48 x 36 x 15 cm |
14 x 16
x 6.5 in 36 x 41 x 15 cm |
22 x 16 x 6.5 in 56 x 41 x 15 cm |
| Heaters Total Watts | 1000 W | 500 W | 1000 W |
| Overflow Drain | N/A | N/A | N/A |
* When ordering option
listed below, please add the
appropriate suffix to the catalog number when
ordering.
| Heating Device Standard Features | Heating Device Options |
| Water bath temperature range 30 - 100 C. Digital electronic temperature control with LED display. Accuracy ± .5 C Right side function control box with timer for nitrogen and heat. Dry block temperature range 40 - 130 C. High temperature protection switch with automatic reset. |
Intrinsically safe Z purged bath (-Z). Intrinsically safe active type Z purged bath (-ZX). Acid resistant coating (-R) 240 volt wiring and plug, specify plug type (-2) |
| Heating
Device Accessory GFCI electrical adapter, in-line #BP0409 (110 volt only). |
|
Site Navigation Menu: Nitrogen Evaporators:
Introduction / N-EVAP / MULTIVAP Solvent Evaporators:
Introduction / S-EVAP-RB / S-EVAP-KD |
|
For